SPECIFICATIONS

Part No.: IS200EXAMG1BAA
Manufacturer: General Electric
Country of Manufacture: United States of America (USA)
Temperature rating: 0 to 60 oC
Product Type: Exciter Attenuation Module
Availability: In Stock
Series: EX2100e

Functional Description

IS200EXAMG1BAA is an Exciter Attenuation Module developed by GE. It is a part of EX2100e excitation system. The Exciter Attenuation Module (EXAM) is an integral component of the ground detection system for the EX2100 Excitation Control system. The component offers robust connectivity and configuration options essential for its effective operation within the system, ensuring reliable performance and compatibility

Features

  • Ground Detection: Combined with the Exciter Ground Detector Module (EGDM), the EXAM detects ground faults within the system.
  • Attenuation: It attenuates signals between the field bus and the EGDM, scaling high voltage from the bridge to a usable level.
  • Mounting: The EXAM is installed within the High Voltage Interface (HVI) module situated in the auxiliary cabinet.
  • Location: Its placement in the HVI module ensures optimal functionality within the system.
  • Interconnection: The EXAM and EGDM(s) are linked via the Exciter Power Backplane (EPBP), facilitating seamless communication.
  • Cabling: A single 9-pin cable establishes the connection between the EXAM and the EPBP, ensuring efficient data transmission.
  • Simplicity and Redundancy: Regardless of the system configuration (simplex or triple modular redundant), only one EXAM is necessary, streamlining installation and maintenance.
  • Consistency in Interconnection: The interconnection remains consistent across different configurations, simplifying integration and troubleshooting processes.

Integration Options

  • Exciter/Regulator Interface: In certain EX2100 versions, the EXAM interfaces with the Exciter/Regulator Options Board (EROC) instead of the EGDM, providing equivalent ground detection functionality.
  • Exciter Ground Detector Module (EGDM): The Exciter Ground Detector Module (EGDM) collaborates with the EXAM to enhance ground detection capabilities within the EX2100
  • Excitation Control system.
  • Computational Power: The Digital Signal Processor Control Board (DSPX) furnishes computational capabilities for the ground detection system, ensuring robust performance.
  • PGDM: The EXAM is also utilized in a standalone simplex ground detector product known as PGDM.
    Integration Components: Interface boards (BGTB and BFGD) and the processor board (BPPB) complement the EXAM in PGDM, offering similar functionality to EX2100-based boards.

Application Data

  • Connectors:
    • Connector J2: This is a 9-pin D connector used for test signal transmission, relay control, and monitoring leakage current.
    • Connector J1: This is a three-pin locking connector that connects to the cable leading to the field flashing relay auxiliary contact, enabling communication and coordination with external components.
  • Stab-on Connectors:
    • E1 and E2: These connectors establish the connection between the field bus voltages and the attenuator module, ensuring seamless transmission and regulation of voltage levels.
  • Terminal:
    • Terminal TB1: This terminal serves as the connection point for linking the EXAM board shield ground to the chassis ground in the cabinet, ensuring proper grounding and electrical safety.
  • Jumpers:
    • Jumpers JP1, JP2, and JP3: These adjustable jumpers configure the module for the various potential transformer (PPT) secondary voltages that may be applied, ensuring compatibility and optimized performance based on the specific voltage requirements of the application.
  • Other Features:
    • Omission of Testpoints, Fuses, and LED Indicators: The EXAM module does not incorporate testpoints, fuses, or LED indicators, focusing instead on essential connectivity and configuration elements.
  • Integration and Configuration:
    • Flexibility and Adaptability: The presence of diverse connectors, terminals, and jumpers enhances the module's flexibility, allowing for seamless integration into different system configurations and environments.
  • Application Flexibility:
    • Customization for PPT Secondary Voltages: The inclusion of adjustable jumpers enables the configuration of the module to accommodate various PPT secondary voltages, providing versatility and adaptability to different power supply setups.

The WOC team is always available to help you with your EX2100e requirements. For more information, please contact WOC.

Frequently Asked Questions

What is IS200EXAMG1BAA?
It is an exciter attenuation module developed by GE under the EX2100e series.

What connectors are available on the EXAM module?
The module features Connector J2, a 9-pin D connector used for test signal transmission, relay control, and monitoring leakage current, and Connector J1, a three-pin locking connector for connecting to the cable leading to the field flashing relay auxiliary contact.

What are the stab-on connectors used for?
Stab-on connectors E1 and E2 establish the connection between the field bus voltages and the attenuator module, ensuring seamless transmission and regulation of voltage levels.

What is the purpose of Terminal TB1?
Terminal TB1 serves as the connection point for linking the board shield ground to the chassis ground in the cabinet, ensuring proper grounding and electrical safety.

How are the jumpers used in the EXAM module?
Jumpers JP1, JP2, and JP3 are adjustable jumpers that configure the module for the various potential transformer (PPT) secondary voltages that may be applied, ensuring compatibility and optimized performance based on the specific voltage requirements of the application.

Does the EXAM module include testpoints, fuses, or LED indicators?
No, the EXAM module does not incorporate testpoints, fuses, or LED indicators. It focuses instead on essential connectivity and configuration elements.

How does the EXAM module enhance system flexibility and adaptability?
The presence of diverse connectors, terminals, and jumpers enhances the module's flexibility, allowing for seamless integration into different system configurations and environments.

Can the EXAM module accommodate various potential transformer (PPT) secondary voltages?
Yes, the inclusion of adjustable jumpers enables the configuration of the module to accommodate various PPT secondary voltages, providing versatility and adaptability to different power supply setups.