IS200EACFG3BAA - Exciter AC Feedback Card

IS200EACFG3BAA - Exciter AC Feedback Card IS200EACFG3BAA - Exciter AC Feedback Card

World Of Controls understands the criticality of your requirement and works towards reducing the lead time as much as possible.

IS200EACFG3BAA - Exciter AC Feedback Card is available in stock which ships the same day.

IS200EACFG3BAA - Exciter AC Feedback Card comes in UNUSED as well as REBUILT condition.

To avail our best deals for IS200EACFG3BAA - Exciter AC Feedback Card, contact us and we will get back to you within 24 hours.

SPECIFICATIONS

Part No.: IS200EACFG3BAA
Manufacturer: General Electric
Country of Manufacture: United States of America (USA)
Temperature Operating: -30 to 65oC
Product Type: Exciter AC Feedback Card
Availability: In Stock
Series: EX2100

Functional Description

IS200EACFG3BAA is an Exciter AC Feedback Card developed by GE. It is a part of the EX2100 control system. The Exciter AC Feedback board is responsible for measuring the exciter Permanent Magnet Generator (PMG) AC supply voltage and current. The EACF (Exciter AC Feedback) board is situated within the exciter auxiliary cabinet.

 Exciter Voltage Measurement

  • G1 Version: This version supports a single three-phase input voltage within the nominal range of up to 480 V rms with a tolerance of +20% at either 50 or 60 Hz.
  • G2 Version: The G2 version is designed to handle a single three-phase input voltage within the nominal range of up to 1000 V rms with a tolerance of +20% at either 50 or 60 Hz.
  • Both versions of the board are equipped with potential transformers that supply a nominal output voltage of 1.6 V rms from their secondary outputs. Additionally, air core current transformers are employed, providing a nominal secondary output voltage ranging from 0 to 0.8 V rms at either 50 or 60 Hz.

Installation

  • Preparation: Open the auxiliary cabinet door and ensure all electrical circuits are tested to confirm that power is off before proceeding.
  • Disconnecting Cables: Carefully disconnect all cables from the board, ensuring adherence to the following steps-
    • Verify that all cables are labeled with the correct connector name, as marked on the board, to simplify reconnection later.
    • For voltage inputs, disconnect the wiring from screw connectors TB1, TB2, and TB3.
    • For the coil inputs, disconnect the wiring at TB4.
  • Handling Mounting Hardware: Exercise caution to avoid dropping any mounting hardware into the equipment, as this could lead to equipment damage or personal injury when power is reapplied.
  • Removing the Board: Remove the three screws that secure the board to the mounting, and carefully detach the board from its position.
  • Installing New Board: Orient the new board in the same position as the one removed, and securely install it onto the standoffs using the three screws removed in the previous step.
  • Reconnecting Cables and Wires: Reconnect all cables and wires to the new board, ensuring that they are properly seated and connected as labeled. This step helps maintain proper functionality and connectivity.
  • Finalization: Once all connections are verified and secured, close the auxiliary cabinet door to complete the replacement process. This ensures the integrity and safety of the system.

The WOC team is always available to help you with your EX2100 requirements. For more information, please contact WOC.

Frequently Asked Questions

What is IS200EACFG3BAA?
It is an Exciter AC Feedback Card developed by GE under the EX2100 series.

Where is the board typically located?
The board is typically located in the exciter auxiliary cabinet.

What is the purpose of the Exciter AC Feedback board?
The Exciter AC Feedback board is designed to measure the exciter PPT AC supply voltage and current.