SPECIFICATIONS

Part No.: IC200CHS001
Manufacturer: General Electric
Country of Manufacture: United States of America (USA)
No. of channels: 4
Voltage Range: 5 V nominal
RTD Types: Platinum, Copper, Nickel, Nickel/Iron
Update Rate: 210 ms
Power Consumption: 125 mA from +5V bus
Product Type: I/O carrier barrier style module
Availability: In Stock
Series: VersaMax

Functional Description

IC200CHS001 is an I/O carrier barrier-style module developed by GE. It is part of the VersaMax series. Barrier-Style I/O Carriers are designed to facilitate the integration and management of input-output modules in industrial automation systems. This carrier is an essential component in the VersaMax series, providing reliable backplane communications and field wiring connections for a single I/O module.

Features

  • Barrier-Style Terminals: Euipped with 36 barrier-style terminals that ensure secure and reliable connections between the I/O module and field wiring. This design reduces the risk of accidental short circuits by maintaining separation between connections, which is essential for uninterrupted communication and system stability.
  • Secure Module Fastening: A latch hole on the carrier allows for the secure fastening of the I/O module. This feature ensures that the module remains firmly in place, even in environments prone to mechanical vibrations or other external disturbances, preventing loose connections.
  • Hinged Transparent Door: The carrier features a hinged transparent door that protects the wiring terminals from dust, debris, and contaminants. This design allows for easy visibility of the wiring connections without the need to open the door, making it convenient for operators to check the status of the connections.
  • Printed Wiring Card: Each I/O module is equipped with a printed wiring card for easy identification and organization of wiring information. The card can be folded and stored inside the hinged door, providing quick access to vital information during maintenance or troubleshooting.
  • Expandable Wiring Connections: Includes notches on the lower edge of the carrier for attaching auxiliary input-output terminal strips. These strips offer additional bussed connection points, providing flexibility to accommodate more complex wiring needs without requiring additional carriers or reconfiguration.

Installation and Mounting

  • DIN Rail Mounting: Designed for easy installation on a 7.5 mm x 35 mm DIN rail, which is standard in industrial settings. The carrier snaps securely onto the rail, allowing for a quick and simple setup. To reduce electromagnetic interference (EMI), it is recommended that the DIN rail be grounded and have a conductive, corrosion-resistant finish.
  • Panel Mounting for Vibration Resistance: In environments with significant mechanical vibration, panel mounting the carrier is recommended. This mounting method provides enhanced stability, ensuring that the carrier and its connections remain secure even in demanding conditions.

Power and Ground Specifications

Accommodate up to 8 Amps for power and ground, or up to 2 Amps per point. It operates with a voltage range of up to 264 Volt AC, and it can handle power surges of up to 300 Volt AC. This high tolerance ensures reliable operation in environments with fluctuating power levels, making the carrier suitable for a wide range of industrial applications.

The WOC team is always available to help you with your Mark I and II requirements. For more information, please contact WOC.

Frequently Asked Questions

What is IC200CHS001?
It is an I/O carrier barrier style module developed by GE under VersaMax series.

What should I do if I need additional field wiring connections?
If additional field wiring connections are needed, you can add auxiliary input-output terminal strips. These strips can be directly inserted into the lower edge, allowing for flexible expansion without needing additional carriers.

Why is it important to ground the DIN rail?
Grounding the DIN rail is important to ensure electromagnetic compatibility (EMC). A grounded, conductive, corrosion-resistant DIN rail helps to mitigate electromagnetic interference, ensuring stable operation of the I/O modules connected to the carrier.

Can the module be used in environments with mechanical vibration?
Yes, the module can be used in environments with mechanical vibration. For such applications, it is recommended to panel-mount the carrier to provide maximum resistance to vibration and ensure the stability of the connections.