IC3600QIXA112 - Interface Jumper Card

IC3600QIXA112 - Interface Jumper Card IC3600QIXA112 - Interface Jumper Card

World Of Controls understands the criticality of your requirement and works towards reducing the lead time as much as possible.

IC3600QIXA112 - Interface Jumper Card is available in stock which ships the same day.

IC3600QIXA112 - Interface Jumper Card comes in UNUSED as well as REBUILT condition.

To avail our best deals for IC3600QIXA112 - Interface Jumper Card, contact us and we will get back to you within 24 hours.

SPECIFICATIONS:

Part Number: IC3600QIXA112
Manufacturer: General Electric
Series: Mark I & II
Product Type: Interface Jumper Card
Number of Jumper Pins: 8
Power Supply Voltage: 28 V dc
Technology: Surface Mount
Redundancy: Simplex
Operating Temperature: -40 to +70°C
Size: 15.9 cm high x 17.8 cm wide
Weight: 0.5 kg
Repair Time: 3-7 Days
Availability: In Stock
Country of Origin: United States

FUNCTIONAL DESCRIPTION:

IC3600QIXA112 is an Interface Jumper Card manufactured and designed by General Electric as part of the Mark I & II Series used in GE Speedtronic Turbine Control Systems. This card allows technicians to control and customize system behavior by altering physical connections without the need for complex rewiring. In turbine control systems, the Interface Jumper Card is particularly essential for routing signals, enabling or disabling specific functions, and switching between operational modes such as maintenance, testing, or normal operation. By adjusting the jumper settings, the control system can be tailored to meet specific operational needs, whether that involves optimizing efficiency, enhancing safety mechanisms, or integrating different hardware components. This flexibility is vital for ensuring that turbines operate safely and efficiently, with the ability to adapt to different conditions or requirements. For instance, in a steam turbine, the Interface Jumper Card might be used to select the most accurate temperature sensor, ensuring optimal performance. Overall, the Interface Jumper Card plays a fundamental role in maintaining control and adaptability within complex industrial systems.

FUNCTIONS:

  • Signal Routing: The card directs electrical signals to specific components within the system, ensuring proper communication and control between different parts of the machinery.
  • Configuration and Customization: It allows for the customization of system settings by connecting or disconnecting circuits. This flexibility enables the system to be tailored to specific operational requirements without the need for extensive hardware modifications.
  • Mode Selection: The card can switch the system between different operational modes, such as normal operation, testing, or maintenance. This is crucial for adapting the system to various stages of operation and ensuring safe functionality during maintenance procedures.
  • Enabling or Disabling Features: By adjusting jumper settings, the card can enable or disable specific features or safety mechanisms within the system. This is vital for ensuring that the system operates within safe parameters under different conditions.
  • Hardware Integration: The card facilitates the integration of various hardware components by establishing the necessary connections. This ensures that all parts of the system work together harmoniously, supporting efficient and reliable operation.
  • Safety and Redundancy: The card can be used to engage redundant safety systems, providing an additional layer of protection by ensuring that the system can shut down safely or continue operating under controlled conditions in the event of a fault.

WOC has the largest stock of OEM replacement parts for GE Speedtronic Control Systems. We can also repair your faulty boards and supply unused and rebuilt boards backed up with a warranty. Our team of experts is available round the clock to support your OEM needs. Our team of experts at WOC is happy to assist you with any of your automation requirements. For pricing and availability on parts and repairs, kindly contact our team by phone or email.

FREQUENTLY ASKED QUESTIONS:

Where are Interface Jumper Cards commonly used?

Interface Jumper Cards are commonly used in industrial control systems, such as turbine control systems, as well as in various electronic devices that require configurable settings. They are crucial in applications where flexibility and precise control are needed.

What are the main functions of an Interface Jumper Card?

The main functions include signal routing, system configuration, mode selection, enabling or disabling features, hardware integration, and safety management. These functions help in customizing the system's operation to meet specific requirements.

How do I know which jumper settings to use?

Jumper settings are typically provided in the system's technical documentation or user manual. These settings may vary depending on the specific application and desired system configuration. It’s important to follow the manufacturer's guidelines to ensure proper operation.