DS3800HSCG1E1E - HI LEVEL ISOLATOR CARD

DS3800HSCG1E1E - HI LEVEL ISOLATOR CARD DS3800HSCG1E1E - HI LEVEL ISOLATOR CARD

World Of Controls understands the criticality of your requirement and works towards reducing the lead time as much as possible.

DS3800HSCG1E1E - HI LEVEL ISOLATOR CARD is available in stock which ships the same day.

DS3800HSCG1E1E - HI LEVEL ISOLATOR CARD comes in UNUSED as well as REBUILT condition.

To avail our best deals for DS3800HSCG1E1E - HI LEVEL ISOLATOR CARD, contact us and we will get back to you within 24 hours.

SPECIFICATIONS

Part No.: DS3800HSCG1E1E
Manufacturer: General Electric
Product Type: High-Level Isolator Board
Series: Mark IV

DS3800HSCG1E1E is a High-Level Isolator Board developed by GE under the Mark IV series. The GE High-Level Isolator Board is made to fit into the drive quickly. On one end, the board has a modular connector, while on the other, it has retention levers. There are additionally 8 jumpers and 1 trimmer resistor on the board.

  • One 34-pin connector with retention levers and one programmable interrupt controller is included in the board. This GE High-Level Isolator Board is part of a high-voltage drive that necessitates meticulous design prior to installation. Because the drive is frequently fitted with other drives and high-voltage equipment, excessive heat is an issue.
  • The drives and equipment generate heat, which must not be allowed to accumulate in the drive room. Fans that are fixed on the walls can be a good option. They keep the heat in the room from building up and transfer the hot air out. Exhaust hoods might be handy as well. They are placed over the equipment and are used to remove hot air and dust from the space.
  • The drive will automatically shut off if the room becomes too hot. A trip condition results as a consequence of this. To protect the drive from damage, the drive recognizes numerous trip situations. Overcurrent is another trip circumstance, in addition to extreme heat. This happens when the drive is exposed to too much power from the power sources. This can harm components, resulting in a fire or injury. Overload is another situation that might cause a trip. When the drive consumes too much current to complete a task, this occurs. It's akin to an overcurrent situation.


The most extensive catalog of GE Speedtronic Mark IV control components may be found at World of Controls. Our experts are ready to assist you with your Mark IV requirements. Please contact WOC right away if you require any additional information.

 

Frequently Asked Questions

 

What is DS3800HSCG1E1E?
DS3800HSCG1E1E is a High-Level Isolator Board developed by GE under the Mark IV series.

How to Obtain DS3800HSCG1E1E?
World of Controls provides DS3800HSCG1E1E as well as other turbine control products. Contact WOC.