SPECIFICATIONS

Part Number: 5463-663
Manufacturer: Woodward
Product Type: Module
Availability: In Stock
Function: HV PS Chassis
Country of Manufacture: United States (USA)

Functional Description

5463-663 is a HV PS Chassis developed by Woodward. It is designed to provide high voltage power supply capabilities for various industrial applications, with a DC input voltage requirement of 24V. The cable connects toward the back of the upper side of the chassis. This design allows for convenient and organized cable routing, ensuring a tidy and efficient installation. To facilitate the connection between the HV PS Chassis and the TMR (Triple Modular Redundancy) Main Chassis, a Power Supply Ribbon cable is used. The ribbon cable has a length of only 1 foot, which means the TMR PS Chassis must be positioned immediately beneath either the A or C Kernels of the TMR Main Chassis. This close proximity enables a direct and efficient connection between the power supply and the TMR Main Chassis.

Features

  • For enhanced redundancy and reliability, a second Chassis-to-Chassis Power Cable can be utilized. This redundant cable provides an additional connection between the HV PS Chassis and the TMR Main Chassis, ensuring uninterrupted power supply in the event of a cable or connection failure. The redundancy feature adds an extra layer of protection and reliability to the power distribution system.
  • The ribbon cable connects to a specific connector located at the back underside of the TMR Main Chassis. This connector is positioned beneath either the A or C Kernels of the TMR Main Chassis. Both of these locations are equipped with connectors, providing flexibility in choosing the appropriate connection point based on the specific configuration and requirements of the system.
  • By utilizing the connectors beneath the A or C Kernels, the HV PS Chassis can establish a secure and reliable electrical connection with the TMR Main Chassis. This connection allows for efficient power transfer and distribution, ensuring the proper functioning of the system.
  • Its cable connection is located toward the back of the upper side of the chassis. The Power Supply Ribbon cable, with a length of 1 foot, connects the HV PS Chassis to the TMR Main Chassis, which should be located directly beneath either the A or C Kernels. Additional redundancy can be achieved with a second Chassis-to-Chassis Power Cable. The ribbon cable connects to a connector beneath the A or C Kernels at the back underside of the TMR Main Chassis, ensuring reliable power distribution within the system.

Characteriistics

  • High voltage power supply: Designed to provide high voltage power to a range of control systems and components, ensuring that they operate reliably and efficiently.
  • SGC output: The chassis is equipped with an SGC (speed governor control) output that provides a stable, ensuring consistent performance of connected systems and components.
  • Robust and reliable: Able to operate reliably in harsh environments, with features such as ruggedized construction, high shock and vibration resistance, and wide temperature ranges.
  • Easy to install: The chassis is designed to be easy to install and use, with clear instructions and intuitive controls.
  • Flexible configuration: It can be configured to meet specific application requirements, with a range of input and output options available.
  • Efficient power management: Designed to minimize power consumption, reducing energy costs and improving overall efficiency.

World of Controls has the most comprehensive selection of GE and Woodward components. Our professionals are available to help you with your requirements at any time. If you require any additional information, please contact WOC immediately.

Frequently Asked Questions

What is 5463-663?
It is a HV PS Chassis developed by Woodward.

Where does the cable connect on the Power Supply Chassis?
The cable connects toward the back of the upper side of the Power Supply Chassis.

What is the purpose of positioning the TMR PS Chassis beneath the A or C Kernels?
Placing the TMR PS Chassis in close proximity to the A or C Kernels ensures a direct and efficient electrical connection using the Power Supply Ribbon cable, facilitating proper power distribution within the TMR system.

How is the Power Supply Ribbon cable connected to the TMR Main Chassis?
The ribbon cable connects to a connector located at the back underside of the TMR Main Chassis, specifically beneath the A or C Kernels. Either of these connectors can be used for the power connection.