5461-772 - Temperature Control Module

5461-772 - Temperature Control Module 5461-772 - Temperature Control Module

World Of Controls understands the criticality of your requirement and works towards reducing the lead time as much as possible.

5461-772 - Temperature Control Module is available in stock which ships the same day.

5461-772 - Temperature Control Module comes in UNUSED as well as REBUILT condition.

To avail our best deals for 5461-772 - Temperature Control Module, contact us and we will get back to you within 24 hours.

SPECIFICATIONS

Part Number: 5461-772
Manufacturer: Woodward
Function: Temperature Control Module
Repair: 3-7 Day
Update time: 5 ms
I/O Latency: 1 ms
Product type: Module
Availability: In Stock
Country of Manufacture: United States (USA)

Functional Description

5461-772 is a Temperature Control Module developed by Woodward. The Module is engineered to provide accurate and reliable temperature regulation and is equipped with inputs that allow it to measure temperature using various temperature sensors such as thermocouples or resistance temperature detectors (RTDs). These sensors provide accurate temperature readings based on the physical properties of the materials being monitored.

Features

  • The Temperature Control Module utilizes advanced control algorithms to accurately regulate the temperature. These algorithms ensure precise control over heating or cooling processes, maintaining the desired temperature setpoints with minimal deviation.
  • Allows for easy adjustment of temperature setpoints to accommodate specific process requirements. Setpoint adjustments can be made through the module's user interface or via external signals from a control system.
  • Proportional-Integral-Derivative (PID) Control: The module may incorporate PID control strategies, which dynamically adjust the output to minimize temperature deviations and stabilize the controlled process. PID control ensures efficient and responsive temperature regulation.
  • Provides output control signals that can be used to actuate various temperature control devices such as heating elements, cooling systems, or valves. These output signals are precisely modulated to achieve the desired temperature control and ensure accurate response.
  • Typically equipped with alarm functions to alert operators in case of temperature excursions beyond predefined thresholds. It may also include safety features such as temperature limits or fault detection mechanisms to prevent damage to the system or equipment.
  • Offer communication interfaces such as serial ports or Ethernet connectivity, allowing integration with broader control systems or monitoring platforms. This enables remote monitoring, configuration, and data logging for temperature-related parameters.
  • Designed to be flexible and expandable, allowing for easy integration into existing control systems or the ability to accommodate future expansion needs.

System Grounding and Shielding

  • According to the RS-422 and RS-485 specifications, a ground wire is required if there is no other ground path between units. The preferred method is to include a separate wire in the cable connecting the circuit grounds. Connect the shield to the ground at only one point.
  • Alternately, connect all circuit grounds to the shield and then connect the shield to earth ground only once. If the latter method is used and the party line contains non-isolated nodes, connect the shield to ground at a non-isolated node rather than an isolated node.

Graphical Application Programmer

  • The GAP software package is an advanced programming environment that includes revision control, security, and code import/export tools to help with program management and code reuse. The "Multi-GAP" functionality allows different entities to create and control multiple sections of control logic and algorithms, which are then compiled into a single program for unit control.
  • While the GAP block language has proven to be an extremely efficient way of programming a turbine controller, some users insist on having their existing sequencing logic run on their new control.
  • Woodward's Ladder Logic Programming tool can be used with GAP to create sequence logic using industry-standard ladder logic programming for these users. This tool allows the user to perform sequencing in the Ladder Logic program language as well as complex control algorithms in GAP.
  • This program, like most industry standard ladder logic programs, allows the user to make sequence changes while the engine is on or off line.

World of Controls has the most comprehensive selection of GE and Woodward components. Our professionals are available to help you with your requirements at any time. If you require any additional information, please contact WOC immediately.

Frequently Asked Questions

What is 5461-772?
It is Temperature Control Module developed by Woodward.

What is the preferred method for including a ground wire in the cable?
The preferred method is to include a separate wire in the cable that connects the circuit grounds of the units.

How should the shield be connected in RS-422 and RS-485 communications?
The shield should be connected to the ground at only one point.

Is there an alternate method for connecting the shield and circuit grounds?
Yes, an alternate method is to connect all circuit grounds to the shield and then connect the shield to earth ground only once.